Bucyrus Newpac DBT Shield Technical Manual BI618932
$30.00
- Type Of Manual: Technical Manual
- Manual ID: BI618932
- Number of Pages: 98
- Size: 2.7MB
- Format: PDF
Product details
-
Model List:
- Newpac DBT Shield
- 1. M00656.pdf
- 1.1. General Safety
- 1.1.1. Residual Risk
- 1.1.1.1. Supplementary Regulations
- 1.1.2. Personnel
- 1.1.3. Operation and maintenance
- 1.1.3.1. Qualification
- 1.1.4. Use in conformance with specifications
- 1.1.5. Use contrary to specifications
- 1.1.6. Safety instructions
- 1.1.6.1. Basic principles
- 1.1.6.2. Prerequisite
- 1.1.6.3. Lighting
- 1.1.6.4. Signalling Systems and Protective Devices
- 1.1.6.5. Emergency Stop
- 1.1.6.6. Support Lock-out Switch
- 1.1.6.7. Moving Parts
- 1.1.6.8. Automatic Mode
- 1.1.7. Storage and transport
- 1.1.8. Installation
- 1.1.9. Operation
- 1.1.10. Maintenance
- 1.1.10.1. Hydraulics
- 1.1.10.2. Handling of Hydraulic Fluids
- 1.1.10.3. Maintenance and Repair
- 1.1.10.4. Permissible Hoses
- 1.1.10.5. Installation of Hydraulic Hoses
- 1.2. Storage and transport
- 1.2.1. Storage
- 1.2.1.1. Storage of new equipment
- 1.2.1.2. Exposure to Sunlight
- 1.2.1.3. Natural Ageing
- 1.2.1.4. Moisture and Dirt
- 1.2.1.5. Short Term Storage
- 1.2.1.6. Long Term Storage
- 1.2.1.7. Plastic Deformation
- 1.2.1.8. Random Sample Inspection
- 1.2.1.9. HFA Fluids
- 1.2.2. Used equipment
- 1.2.2.1. Corrosion Protection
- 1.2.3. Transport
- 1.2.3.1. Transport Units
- 1.2.3.2. Points of Attachment
- 1.2.3.3. Temperatures Below Freezing
- 1.2.3.4. Electrical and Electronic Components
- 1.2.3.5. Transport Safety Devices and Transport Units
- 1.3. Introduction
- 1.3.1. General Data Information
- 1.4. One Web Back System (OWB)
- 1.5. Face and Gate End Shields
- 1.6. Safe Working Areas
- 1.6.1. Front Walkway
- 1.7. Corrosion Protection
- 1.7.1. Emulsion / Water / Oil Monitoring
- 1.7.2. Quality of Processed Water
- 1.7.3. Emulsion values
- 1.8. Hydraulic Bleed Points
- 1.8.1. Operation Screw Type
- 1.8.2. Operation Manometer Gauge Port Type
- 1.9. Control Unit Troubleshooting
- 1.9.1. No response when selecting a function
- 1.9.1.1. Corrective Action
- 1.9.2. Bypassing or Sticking High or Low Flow Valves
- 1.9.3. Replacing High/Low Flow Valve
- 1.9.4. Double Solenoid Pilot Valve Replacement
- 1.9.5. Control Block Filter and Pilot Non-Return Valve Replacement
- 1.10. Cylinder Replacement
- 1.10.1. Advancing Cylinder Replacement
- 1.10.2. Leg Cylinder Replacement
- 1.10.3. Base Cylinder Replacement
- 1.10.4. Stabilising Cylinder Replacement
- 1.10.5. Side Shield Cylinder Replacement
- 1.10.6. Anti-Topple Cylinder
- 1.10.7. Inter-Shield Hose Replacement
- 1.11. Shields Maintenance (Electrical System)
- 1.11.1. SCU Port Assignments
- 1.11.1.1. PMC-R Port Assignments
- 1.11.2. SKK Cables and Power Supply Testing
- 1.11.3. Pressure Sensor Information
- 1.11.4. Reed Rod Information
- 1.11.5. Faulty Sensor Indication
- 1.11.6. PMC-R Power Adaptor
- 1.11.7. PMC-R Isolation Coupler
- 1.12. Shields Maintenance (Electrical) Fault Finding
- 1.12.1. Power Group without Power
- 1.12.2. Support Is Not Operating
- 1.12.2.1. Possible Reason
- 1.12.2.2. Corrective Action
- 1.12.2.3. If no LED on the Solenoid valve operated
- 1.12.2.4. Change the solenoid driver.
- 1.12.3. Single SCU without Power
- 1.12.4. No Server SCU in the Network
- 1.12.4.1. Possible Reason
- 1.12.4.2. Corrective Action
- 1.12.5. Single PMC-R Reboots on Power Up
- 1.12.6. No Hydraulic Flow Pressure
- 1.12.7. SRB Auto Sequence Stops
- 1.12.8. Network Drops Out During Operation
- 1.12.9. Incomplete Network
- 1.12.9.1. Broken cable or faulty SCU
- 1.12.10. When Operating a Support Function, the Power Drops Off and R
- 1.12.11. During Auto sequence Support Does not Move
- 1.12.12. Bankpush Not Completed
- 1.12.13. PMC-R Error messages